Supported Sub-components

Sensors, buttons, and select menus can be added to the configuration for additonal functionality. This page lists the available components with example configuration.

Sensors​

Sensors provide additional information from the equipment. Not all sensors are available on all systems; see sensor notes for additional information.

binary_sensor:
- platform: mitsubishi_itp
defrost:
# Reports if system is in defrost
name: "Defrost"
filter_status:
# Reports if filter needs to be replaced (false = OK)
name: "Filter Status"
isee_status:
# Reports if i-see is enabled
name: "i-see Status"
preheat:
# Reports if system is preheating
name: "Preheat"
standby:
# Reports if system is in standby
name: "Standby"
using_internal_temperature:
# Reports if system is using internal temperature sensor
name: "On Internal Temperature"

sensor:
- platform: mitsubishi_itp
compressor_frequency:
# Frequency in Hz of compressor (only some equipment)
name: "Compressor Frequency"
outdoor_temperature:
# Outdoor temperature as reported by equipment
name: "Outdoor Temperature"
input_watts:
name: "Input Watts"
lifetime_kwh:
name: "Lifetime kWh"
runtime:
name: "Runtime"

# Only available if a thermostat is connected
thermostat_humidity:
# Humidity reported by thermostat (only with enhanced_mhk)
name: "Thermostat Humidity"
thermostat_temperature:
# Temperature reported by thermostat
name: "Thermostat Temperature"

text_sensor:
- platform: mitsubishi_itp
actual_fan:
# Actual current fan speed (vs. set speed)
name: "Actual Fan"
error_code:
# Reports diagnostic error code
name: "Error Code"

# Only available if a thermostat is connected
thermostat_battery:
# Thermostat battery status (only with enhanced_mhk)
name: "Thermostat Battery"

Sensor Notes​

outdoor_temperature​

The outdoor_temperature sensor seems to provide values inconsistently. It's possible that the byte containing the value has a flag in it, and it seems like the temperature is only reported under certain conditions.

actual_fan​

While the unit is preheating or at set-point, sometimes the fan will be running at a speed other than the requested one; this sensor reports that "actual" speed.

Buttons​

A button can be added to reset the filter change status:

button:
- platform: mitsubishi_itp
filter_reset_button:
name: "Filter Reset"

Selects​

Vane Control​

On units with vertical or horizontal vane control, the following components can be added to the configuration to enable control.

select:
- platform: mitsubishi_itp
vane_position:
name: "Vane Position"
horizontal_vane_position:
name: "H. Vane Position"

Temperature Source Select​

See adding extra temperature sources.

Switches​

Zone Control​

On supported units, each switch controls one zone. At least one zone needs to be configured for zones to be enabled.

switch:
zone_1:
name: "Zone 1"
...
zone_9:
name: "Zone 9"