Supported Sub-components

Sensors, buttons, and select menus can be added to the configuration for additonal functionality. This page lists the available components with example configuration.

Sensors

Sensors provide additional information from the equipment. Not all sensors are available on all systems; see sensor notes for additional information.

binary_sensor:
- platform: mitsubishi_itp
defrost:
# Reports if system is in defrost
name: "Defrost"
filter_status:
# Reports if filter needs to be replaced (false = OK)
name: "Filter Status"
isee_status:
# Reports if i-see is enabled
name: "i-see Status"
preheat:
# Reports if system is preheating
name: "Preheat"
standby:
# Reports if system is in standby
name: "Standby"

sensor:
- platform: mitsubishi_itp
compressor_frequency:
# Frequency in Hz of compressor (only some equipment)
name: "Compressor Frequency"
outdoor_temperature:
# Outdoor temperature as reported by equipment
name: "Outdoor Temperature"

# Only available if a thermostat is connected
thermostat_humidity:
# Humidity reported by thermostat (only with enhanced_mhk)
name: "Thermostat Humidity"
thermostat_temperature:
# Temperature reported by thermostat
name: "Thermostat Temperature"

text_sensor:
- platform: mitsubishi_itp
actual_fan:
# Actual current fan speed (vs. set speed)
name: "Actual Fan"
error_code:
# Reports diagnostic error code
name: "Error Code"

# Only available if a thermostat is connected
thermostat_battery:
# Thermostat battery status (only with enhanced_mhk)
name: "Thermostat Battery"

Sensor Notes

outdoor_temperature

The outdoor_temperature sensor seems to provide values inconsistently. It's possible that the byte containing the value has a flag in it, and it seems like the temperature is only reported under certain conditions.

actual_fan

While the unit is preheating or at set-point, sometimes the fan will be running at a speed other than the requested one; this sensor reports that "actual" speed.

Buttons

A button can be added to reset the filter change status:

button:
- platform: mitsubishi_itp
filter_reset_button:
name: "Filter Reset"

Selects

Vane Control

On units with vertical or horizontal vane control, the following components can be added to the configuration to enable control.

select:
- platform: mitsubishi_itp
vane_position:
name: "Vane Position"
horizontal_vane_position:
name: "H. Vane Position"

Temperature Source Select

See adding extra temperature sources.