Command 0x08 - Set Run State

Seems to correlate (at least partially) with 0x62 0x09 - Get Run State. Name/other flags TBD.

BytePurposePossible ValuesSupported by mUARTNotes
0Command Type0x08Yes
1-2Update FlagsTraditional hex flagsPartiallyIndicates which parameters to update.
3Filter Reset0x00: No
0x01: Yes
Update flag 0x0100
4*(UNCONFIRMED) Dehumidify Value0x00 to 0x64Update flag 0x0400
5*(UNCONFIRMED) Power Saving Mode0x00: Off
0x0A: On
Update flag 0x0800
6**Airflow control mode (i-See)Airflow control modeUpdate flag 0x2000
Not all values supported for all units.
7*(UNCONFIRMED) Buzzer0x00: No
0x01: Yes
Update flag 0x1000
Sending 0x01 results in some units beeping twice
11*(UNCONFIRMED) Notification for remote control navigation0x02 : 0x00Update flag 0x0002

*Extracted from Android app 霧ヶ峰REMOTE (v5.3.1)

**Tested on MSZ-LN25VG2W

Airflow control mode (i-See)

ValueName
0EVEN
1DIRECT
2INDIRECT

Confirmed to work on units with the i-See sensor and the DIRECTION key on the IR remote (e.g. MSZ-LN##VG#*). The mode can only be set when the horizontal vane field is set to 0x80 and the i-See sensor is activated on the unit.