Skip to main content

Command 0x06 - Get Operation State

note

This packet's information was pulled from SwiCago's HeatPump library. It has not been observed over the wire without specifically requesting command 0x06.

This command returns diagnostic (?) information about the heat pump's operating state. This command does not appear to be used as part of normal heat pump operation.

BytePurposePossible ValuesSupported by mUARTNotes
0CommandType0x06
3CompressorFrequencyVariableYesThe current compressor frequency in Hertz. Not supported/reported by all units.
4Operating0x00, 0x01YesA boolean indicating whether the heat pump is operating.
5-6Input Power (Watts)VariableNoReported by EChatvet's lib in watts. Unconfirmed, not supported by all units.
7-8Lifetime Power ConsumptionVariableNoReported by EChatvet's lib in 100Wh increments. Unconfirmed, not supported by all units.
11???0x00, 0x42No

Sample Packets

[FC.62.01.30.10]06.00.00.00.01.00.00.00.00.00.00.00.00.00.00.00 56  // SVZ-KP30NA
[FC.62.01.30.10]06.00.00.00.00.00.00.00.78.00.00.42.00.00.00.00 9D // MSZ-GS12NA
[FC.62.01.30.10]06.00.00.00.00.00.00.00.79.00.00.42.00.00.00.00 9C // MSZ-GS12NA