Command 0x06 - Get Operation State
note
This packet's information was pulled from SwiCago's HeatPump library. It has
not been observed over the wire without specifically requesting command 0x06.
This command returns diagnostic (?) information about the heat pump's operating state. This command does not appear to be used as part of normal heat pump operation.
| Byte | Purpose | Possible Values | Supported by mUART | Notes |
|---|---|---|---|---|
| 0 | CommandType | 0x06 | ||
| 3 | CompressorFrequency | Variable | Yes | The current compressor frequency in Hertz. Not supported/reported by all units. |
| 4 | Operating | 0x00, 0x01 | Yes | A boolean indicating whether the heat pump is operating. |
| 5-6 | Input Power (Watts) | Variable | No | Reported by EChatvet's lib in watts. Unconfirmed, not supported by all units. |
| 7-8 | Lifetime Power Consumption | Variable | No | Reported by EChatvet's lib in 100Wh increments. Unconfirmed, not supported by all units. |
| 11 | ??? | 0x00, 0x42 | No |
Sample Packets
[FC.62.01.30.10]06.00.00.00.01.00.00.00.00.00.00.00.00.00.00.00 56 // SVZ-KP30NA
[FC.62.01.30.10]06.00.00.00.00.00.00.00.78.00.00.42.00.00.00.00 9D // MSZ-GS12NA
[FC.62.01.30.10]06.00.00.00.00.00.00.00.79.00.00.42.00.00.00.00 9C // MSZ-GS12NA