Skip to main content

Command 0x42 - HVAC Options

These options are extracted from an MSZ-AY HVAC device.

Returns the boolean whether the option is currently active or not.

It cannot be set with the 0x41 - Set Request.

BytePurposePossible ValuesNotes
0Command Type0x42
1Air Purifier0x00 or 0x01Plasma Quad filter active or not
2Night Mode0x00 or 0x01Dims the LED status
3Circulator*0x00 or 0x01In HEAT only. When target is reached outdoor unit stops and indoor continues FAN operation.

*might be same byte as the mode ECONO COOL? May be different functions on different units

Sample Packets

[FC.62.01.30.10] 42.01.00.00.00.00.00.00.00.00.00.00.00.00.00.00 1A  // MSZ-AY35VGKP
[FC.62.01.30.10] 42.01.01.01.00.00.00.00.00.00.00.00.00.00.00.00 18 // MSZ-LN25VG2W